HZLAB20261013返回 Back
马来西亚

Materials/ Products 
Tested
Type of Test/ 
Properties Measured/ 
Range of Measurement
Standard Test Methods/ 
Equipment/Techniques
Water Extract of Productsfor 
Use in Contact with Drinking 
Water including main water 
service, bore water, rain water, 
filtered water (i.e. distilled, 
reverse osmosis and deionized
water)
Extractant Water -Drinking 
Water including main water 
service, bore water, rain 
water, filtered water (i.e. 
distilled, reverse osmosis and 
deionizedwater)
Taste AS/NZS 4020, Appendix C
Odour and flavor BS 6920-2.2.1
BS 6920-2.2.2
BS 6920-2.2.3
MS 1583, Part 2, Section 2
SS 375:Part 2.2
Growth of aquatic 
microorganism
AS/NZS 4020, Appendix E
BS 6920-2.4
MS 1583, Part 2, Section 4
SS 375:Part 2.4
Materials/ 
Products Tested
Type of Test/ 
Properties Measured/ 
Range of Measurement
Standard Test Methods/ 
Equipment/Techniques
Water Extract of Productsfor 
Use in Contact with Drinking 
Water including main water 
service, bore water, rain 
water, filtered water (i.e. 
distilled, reverse osmosis 
and deionizedwater)
Extractant Water -Drinking 
Water including main water 
service, bore water, rain 
water, filtered water (i.e. 
distilled, reverse osmosis 
and deionized water) 
(cont.)
Cytotoxic activity AS/NZS 4020, Appendix F
BS 6920-2.5
MS 1583, Part 2, Section 5
SS 375:Part 2.5
Mutagenicity activity AS/NZS 4020, Appendix G
Materials/ 
Products Tested
Type of Test/ 
Properties Measured/ 
Range of Measurement
Standard Test Methods/ 
Equipment/Techniques
Productsfor Use in Contact 
with Drinking Water
Appearance of Water Extract with 
respect to Colour and Turbidity
AS/NZS 4020, Appendix D & J
Suitability of non-metallic 
products for use in contact 
with water intended for human 
consumption with regard to 
their effect on the quality of 
the water.
Appearance of Water Extract with 
respect to Colour and Turbidity
MS 1583:2003, Part 2, Section 3
MS 1583:2003, Part 3
BS 6920-2.3:2000+A1:2014
BS 6920-3:2000
SS 375:Part2.3
SS 375:Part 3
Drinking Water including main 
water service, bore water, rain 
water, filtered water (distilled, 
reverse osmosis and 
deionized water)
Colour ISO 7887, Method C, Option 1
APHA 2120 C
Turbidity ISO 7027-1
APHA 2130 B
Water Grading -Grade 2 & 3 BS EN ISO 3696, Clause 7.1 -
7.5
pH APHA 4500-H B
Conductivity APHA 2510 B
Materials/ 
Products Tested
Type of Test/ 
Properties Measured/ 
Range of Measurement
Standard Test Methods/ 
Equipment/Techniques
Materials and articles in 
contact with Foodstuffs 
(plastics)
Overall migration into aqueous 
food simulants by total 
immersion
Ultrapure water 
Acetic acid 3%
Ethanol10%
Ethanol20%
Ethanol 50%
Ethanol95%
BS EN 1186-3:2022 (Method 1)
EU 10/2011 and its amendment 
(2016/1416,2017/752, 2018/831, 
2020/1245)
Overall migration into aqueous 
food simulants by pouch 
Ultrapure water
Acetic acid 3%
Ethanol10%
Ethanol20%
Ethanol 50%
Ethanol95%
BS EN 1186-3:2022 (Method 3&4)
EU 10/2011 and its amendment 
(2016/1416,2017/752, 2018/831, 
2020/1245)
Overall migration into aqueous 
food simulants by filling 
Ultrapure water
Acetic acid 3%
Ethanol10%
Ethanol20%
Ethanol 50%
Ethanol95%
BS EN 1186-3:2022 (Method 5)
EU 10/2011 and its amendment 
(2016/1416, 2017/752, 2018/831, 
2020/1245)
‘Substitute test’ for overall 
migrationfrom plastic intended 
come into contact with fatty 
foodstuffs using test media iso-
octane by immersion, pouch and
filling
BS EN 1186-3:2022 (Method 
1,2,3,4&5)
EU 10/2011 and its amendment 
(2016/1416,2017/752,2018/831, 
2020/1245)
Materials/ 
Products Tested
Type of Test/ 
Properties Measured/ 
Range of Measurement
Standard Test Methods/ 
Equipment/Techniques
Vitreous china used in 
sanitary appliances
Chemical Resistance AS 1976, Appendix C
Drinking water treatment 
appliances
Chlorine reduction AS/NZS 4348, Appendix D, 
D6.1-Test 1
NSF/ANSI 42, Clause 7.3.3
Metal and alloys
-washer & wire on bolt
Corrosion test expressed as 
mass loss
ISO 7441
Metals and coating products Corrosion test (salt spray) ASTM B117 
ISO 9227
IEC 60068-11
MIL-STD-883G. Method 1009.8 
AS2331.3.1
AS2331.3.2
AS2331.3.3
BS 3900-F4
Unplasticized PVC Fitting for
cold water service
Resistance to sulphuric acid SS 174
Unplasticized PVC Pipe for 
cold water service
Resistance to Acetone SS 141
Resistance to sulphuric acid
Materials/ 
Products Tested
Type of Test/ 
Properties Measured/ 
Range of Measurement
Standard Test Methods/ 
Equipment/Techniques
Tapwares FinishedSurface BS EN 248:2002
Flow Rate BS EN 200:2008, Clause 10
SPAN TS 3004:2021, Clause 8.2
SPAN TS 3012:2022, Clause 8.2
ASME A112.1-2012/CSA
B125.1-12, Clause 5.4
Water Efficiency AS/NZS 6400:2016, Clause 4.4
SPAN TS 3004:2021, Clause 8.1
SPAN TS 3012:2022, Clause 8.1
Marking AS 3718:2021, Clause 1.5
SPAN TS 3004:2021, Clause 9
SPAN TS 3012:2022, Clause 7
Dimension SPAN TS 3004:2021, Clause 6
SPAN TS 3012:2022, Clause 6
Shower Head Finish Surface BS EN 248:2002
Flow Rate AS 3662-2013, Clause5.1,
SPAN TS 3005:2021, Clause 6.2
ASME A112.18.1-2012/CSA
B125.1-12, Clause 5.4
Water Efficiency SPAN TS 3005:2021, Clause 6.1
Leak-tightness SPAN TS 3005:2021, Clause 6.3
Marking AS 3662-2013, Clause 6
SPAN TS 3005:2021, Clause 7
Dimension SPANTS 3005:2021, Clause 5
Constant Flow Regulators Flow Rate PUB S&R:2021, Clause 8.1
SS 636:2018+A4:2021, Clause 8.2.5
Materials/ 
Products Tested
Type of Test/ 
Properties 
Measured/ Range 
of Measurement
Standard Test Methods/ 
Equipment/Techniques
Water Pumps:
Fixed Fire Fighting 
System-Fire 
Pumps & 
Centrifugal Pumps
Rotodynamic pumps-
hydraulic performance 
acceptance test Grade 1, 2 & 
3 Range:
Flow: Up to 950 m3/h
Positive Pressure: Up to 16 
bars
ISO 9906:2012
ANSI/HI11.6:2017
ANSI/HI14.6:2016
MS 2616:2015, Clause 11.3.2.2 & 
Clause 11.3.3
Hydrostatic pressure
Pressure: Up to 25 bars
BS EN 12162:2001+A1:2009, Clause 
7.2 &Clause10
EN 12162:2001+A1:2009, Clause 7.2 
& Clause10
Materials/ 
Products Tested
Type of Test/ 
Properties Measured/ 
Range of
Measurement
Standard Test 
Methods/ 
Equipment/Techniqu
es
Induction Motors Type test:
Voltage and Current
Range:
Voltage: 0V –415 V, 3 phase, 
50Hz
Current: 0V –600A, 3 phase
Power: up to 315kW
IEC 60034-1:2017, Clause 5.5.3