16 CFR PART 1632 FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4–72, AMENDED)
床垫,床衬垫的香烟闷烧测试标准
Test Clause Requirement
Conditioning T: ³ 65ºF, H: less than 55%  at least 48h
requirements 1) No obvious flaming combustion occurs.
2) Smoldering continues should be less than 5 minutes after cigarette has extinguished.
3)The char develops should be less than two inches in any direction from the cigarette, including laterally or downward into the mattress or pad.
Mattress pads containing a chemical fire retardant should be washed and dried 10 times before testing, except the one time use pads.
Mattress Pads
Washing and drying test  AATCC 124-82, 10 times
Test Sample: 6 sets of completed products or prototypes
Ticking Test
Sample required 6 pcs 50.8 cm × 50.8cm
Turnaround time: Regular (9 working days)

 
Picture for Reference 参考图片: